| Model |
A-LAS-34/90 |
| Dimensions |
Transmitter and receiver: LxWxH = 94 mm x 34 mm
x 50 mm(without connector) |
| Available apertures |
Transmitter: 30x2, 25x2, 20x2, 10x2, 5x2
(mm), |
| |
Receiver: 30x0.5, 25x0.3, 20x0.3, 10x0.3, 5x0.3
(mm) |
| Max. range |
Depends on the aperture used: With 2 mm wide
transmitter aperture max. 3 m, |
| |
with 0.3 mm wide transmitter aperture max. 0.3
m |
| Reproducibility |
With aperture size 5 mm: typ. 1% of aperture
size, |
| |
with aperture size 10 mm: typ. 0,5% of aperture
size, |
| |
with aperture size starting from 20 mm: typ.
0,2% af aperture size, |
| |
with threshold correction (via amplifier): typ.
0,1% of aperture size |
| Optical filter |
Interference filter and polarisation
filter |
| Analog output |
0 ... +10V, band width analog signal: 100 kHz
(- 3dB) |
| Linearity |
With aperture 5 mm: 0.3%, with aperture 10 mm:
1%, with aperture 25 mm: 2% |
| Operating temperature |
-20°C ... +50°C |
| Temperature drift |
10°C ... +50°C: typ. 0.5% of measuring
range (aperture size) |
| Type of connector |
Transmitter: 3-pin M8-connector, receiver:
4-pin M8-connector |
| Housing material |
Aluminum, anodized in blue |
| Enclosure rating |
IP67 |