| Model |
R-LAS-LT-80-WA |
| Dimensions |
LxWxH = 68 mm x 40 mm x 42.5 mm (without
connector) |
| Working range |
typ. 79 ... 81 mm, with type "XL": typ. 70 ...
95 mm, with "XL-LIN": typ. 74 ... 86 mm |
| Reproducibility |
typ. 10 µm, with type "XL": typ. 0.2 mm,
with type "XL-LIN": typ. 0.1 mm |
| |
(depends on the surface of the measured
object) |
| Optical filter |
Red light filter RG630 and interference
filter |
| Voltage supply |
+12VDC ... +32VDC, reversed polarity protected,
overcurrent protected |
| Interface |
RS232 |
| Operating temperature |
-20°C ... +55°C |
| Parameterisable under Windows® |
Bright/dark switching, laser power correction,
pulse lengthening, averaging |
| Outputs |
1x tolerance output, 1x reference output (100
mA, short-circuit-proof) |
| |
with "ANA": 1x analog (0 ... +10V), 1x
reference output (100 mA, short-circuit-proof) |
| Switching state indication |
By means of an orange LED |
| Switching frequency |
Typ. 3 kHz |
| Housing material |
Aluminum, anodized in blue |
| Enclosure rating |
IP67 |