L-LAS-LT-XL Series
Laser distance line sensors (big measuring range)General technical data ....
GENERAL TECHNICAL DATA:
Software | Windows® PC software: L-LAS-LT-Scope |
Variants | ►Standard: Analog output 0...+10V ►-4/20: Analog outputs 0...+10V and 4...20mA |
Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
Current consumption | <200mA |
Max. switching current | 100mA, short-circuit proof |
Light source | Semi-conductor laser, 670 nm, <1mW opt. power, DC-operation, Laser class 2 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Line detector | depends on sensor type |
Measuring range | depends on sensor type |
Resolution/reproducibility | depends on sensor type |
Linearity | depends on sensor type |
Laser line geometry | depends on sensor type |
Optical filter | Interference filter |
Analog output | Voltage 0...+10V ►with L-LAS-LT-...-4/20: Voltage 0...+10V and current 4...20mA |
Digital outputs | OUT0: (-) Measuring value < lower tolerance threshold OUT1: (+) Measuring value < upper tolerance threshold pnp bright-switching/npn dark-switching or pnp dark-switching/npn bright-switching Output polarity adjustable under Windows® on PC |
Digital inputs | IN0: External trigger IN1: Teach/Reset (double function) Input voltage +Ub/0V, with protective circuit |
Sensitivity | adjustable under Windows® on PC |
Laser power correction | adjustable under Windows® on PC |
Temperature stability | 0,01% of measuring range/°C |
LED display | 2x two-color LED red/green and 1x two-color LED yellow/green for tolerance band monitoring: red (+): Measuring value > upper tolerance threshold red (-): Measuring value < lower tolerance threshold green (ok): Measuring value within tolerance window 1x two-color LED yellow/green (multifunctional): yellow: Power indicator |
Scan frequency | depends on sensor type |
Interface | RS232, parameterizable under Windows® |
Housing dimensions | depends on sensor type |
Housing material | Aluminum, anodized in black |
Type of connector | - to PLCSPS: 8-pole fem. connector Binder 712 - to PC: 4-pole fem. connector Binder 707 |
Connecting cables | - to PLC: cab-las8/SPS - to PC: cab-las4/PC, cab-4/USB or cab-4/ETH |
Operating temp. range | -10°C ... +50°C |
Storage temp. range | -20°C ... +85°C |
Enclosure rating | Electronics: IP54, optics: IP67 |
EMC test acc. to | DIN EN 60947-5-2 |