L-LAS-LT-SL Series
Laser distance line sensors (Slim Line)General technical data ....
GENERAL TECHNICAL DATA:
Software | Windows® PC software: L-LAS-LT-Scope |
Variants | ►-P: Visible red laser spot (typ. Ø 0.3mm) ►-L: Visible red laser line (typ. 0.3mm x 3mm) |
Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
Current consumption | <200mA |
Max. switching current | 100mA, short-circuit proof |
Light source | L-LAS-LT-30-SL-P / -SL-L L-LAS-LT-50-SL-P / -SL-L L-LAS-LT-80-SL-P / -SL-L L-LAS-LT-130-SL-P / -SL-L L-LAS-LT-180-SL-P ►Semi-conductor laser, 670 nm, <0.39mW opt. power, DC-operation, Laser class 1 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) L-LAS-LT-180-SL-L L-LAS-LT-350-SL-P / -SL-L L-LAS-LT-600-SL-P / -SL-L ►Semi-conductor laser, 670 nm, <1mW opt. power, DC-operation, Laser class 2 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Line detector | CMOS, 512 pixel, 4096 subpixel |
Measuring range | depends on sensor type |
Resolution/reproducibility | depends on sensor type |
Linearity | depends on sensor type |
Laser line geometry | ►-P: Visible red laser spot (typ. Ø 0.3mm) ►-L: Visible red laser line (typ. 0.3mm x 3mm) |
Optical filter | Interference filter, red light filter |
Analog outputs (2x) | Voltage 0...+10V and current 4...20mA |
Digital outputs (2x) | OUT0: (-) Measuring value < upper tolerance threshold OUT1: (+) Measuring value > upper tolerance threshold pnp bright-switching/npn darks-switching or pnp dark-switching/npn bright-switching Output polarity can be adjusted under Windows® on PC |
Digital inputs (2x) | IN0: External trigger IN1: Teach/Reset (double function) Input voltage +Ub/0V, with protective circuit |
Sensititivy | adjustable under Windows® on PC |
Laser power correction | adjustable under Windows® on PC |
Temperature stability | 0.01% of measuring range/°C |
LED display | 1x three-color LED red/green/blue for tolerance band monitoring: red = Measuring value outside the tolerance window green = Measuring value within tolerance window blue = Measuring value outside the measuring range 1x three-color LED red/green/blue for power indication: green = Power |
Scan frequency | max. 2kHz (at video speed = NORMAL) or max. 3.3kHz (at video speed = FAST) |
Interface | RS232, parameterizable under Windows® |
Housing dimensions | depends on sensor type |
Housing material | Aluminum, anodized in black |
Type of connector | - to PLC: 8-pole fem. connector Binder 713/763 - to PC: 4-pole fem. connector Binder 707 |
Connecting cables | - to PLC: cab-M12/8-g-...-shd - to PC: cab-las4/PC, cab-4/USB or cab-4/ETH |
Operating temp. range | -10°C ... +50°C |
Storage temp. range | -20°C ... +85°C |
Enclosure rating | Electronics: IP54, optics: IP67 |
EMC test acc. to | DIN EN 60947-5-2 |