Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

GLAST Series

Gloss and structure sensors


General technical data ....

Type Light source Angle of incidenceMeasuring distance (recommended)Detection rangeLxWxH (mm) Data
sheet
CAD
data
Appl.
GLAST-85-30°/30°-DIF-... 16 super bright white light LED, diffusor and line grid (available line grid types: -0.5/0.5
-1.0/1.0
-2.0/2.0)
Optical axes of lighting units are inclined each at an angle of 30° from the normal (vertical)typ. 85mm ± 5mmMeasuring length typ. 20mm at distance 85mm171.1x87.76x34
Appl.
GLAST-85-45°/45°-DIF-... 16 super bright white light LED, diffusor and line grid (available line grid types: -0.5/0.5
-1.0/1.0
-2.0/2.0)
Optical axes of lighting units are inclined each at an angle of 45° from the normal (vertical)typ. 85mm ± 5mmMeasuring length typ. 20mm at distance 85mm204.3x110.31x34
GLAST-135-0°-... 16 super bright white light LED, diffusor and line grid (available line grid types: -0.5/0.5
-1.0/1.0
-2.0/2.0)
Split version: Transmitter and receiver in separate housings, arranged opposite (0°), including mounting angle135mmMeasuring length typ. 20mm at distance 135mmT/R: each 135x55x34
Gesamt (incl. mounting angle): 600x323x34


GENERAL TECHNICAL DATA:
Software Windows® PC software: STRUCT-Scope
Voltage supply +24VDC (± 10%), reversed polarity protected, overload protected
Current consumption <500mA
Max. switching current 100mA, short-circuit proof
Switching state indication 5 yellow LED (OUT0 ... OUT4)
Input digital 1x digital input: IN0 (0V/+24V)
Output digital 5x digital output: OUT0 ... OUT4 (0V/+24V)
Interface RS232 (USB and Ethernet adaptor available)
Pulse lengthening 100ms ... 1s, adjustable via PC software
Averaging max. 32 values, adjustable via PC software
Line grid Various line grid types are available:
0.5/0.5: 0.5mm line width and 0.5mm spacing
1.0/1.0: 1mm line width and 1mm spacing
2.0/2.0: 2mm line width and 2mm spacing
Max. measuring frequency typ. 10Hz
Angle of incidence depends on sensor type
Transmitter (light source) depends on sensor type
Transmitter control can be switched via PC software:
Alternatinv light operation (LED MODE-AC),
Direct light operation (LED MODE-DC)
Measuring distance depends on sensor type
Receiver Line detector (512 pixel), projection objective, apertured diaphragm 1mm
Exposure time Exposure time adjustable via PC software (EXPOSURE TIME)
Detection range depends on sensor type
Temperature drift X,Y deltaX/deltaT, deltaY/deltaT: typ. 0.2 digits/°C (< 0.01%/°C)
Resolution 20mm/4096
Memory capacity max. 5 spatial frequency spectra (max. 31 structures)
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in black (optics holding device: anodized)
Type of connector - to PLC: 8-pole fem. connector Binder 712
- to PC: 4-pole fem. connector Binder 707
Connecting cables - to PLC: cab-las8/SPS
- to PC: cab-las4/PC, cab-4/USB or cab-4/ETH
Operating temp. range -20°C ... +55°C
Storage temp. range -20°C ... +85°C
Enclosure rating IP64
EMC test acc. to DIN EN 60947-5-2