Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

L-LAS-LT-AL Series

Laser distance line sensors (Advanced Line)


General technical data ....

Type Light sourceMeas. range (begin...end)Resolution/ repro-ducibilityLinea- rityMax. scan frequencyLxWxH (mm) Data
sheet
CAD
data
Appl.
L-LAS-LT-20-AL Line laser, 670nm, <0.4mW (CL. 1)typ. 3.5mm (18mm...21,5mm)1µm / ±1µm0.2% FSR (full scale range)2kHz (NORMAL)
3.8kHz (FAST)
82.26x80x20
L-LAS-LT-38-AL Line laser, 670nm, <0.4mW (CL. 1)typ. 16mm (32mm...48mm)5µm / ±5µm0.2% FSR (full scale range)2kHz (NORMAL)
3.8kHz (FAST)
81.19x65x20
L-LAS-LT-50-AL Line laser, 670nm, <0.4mW (CL. 1)typ. 38mm (36mm...74mm)10µm / ±10µm0.25% FSR (full scale range)2kHz (NORMAL)
3.8kHz (FAST)
82.85x60x20
L-LAS-LT-120-AL Line laser, 670nm, <0.4mW (CL. 1)typ. 120mm (60mm...180mm)30µm / ±30µm0.25% FSR (full scale range)2kHz (NORMAL)
3.8kHz (FAST)
75.6x65x20
L-LAS-LT-165-AL Line laser, 670nm, <1mW (CL. 2)typ. 200mm (75mm...275mm)60µm / ±60µm0.3% FSR (full scale range)2kHz (NORMAL)
3.8kHz (FAST)
74.82x65x20
L-LAS-LT-250-AL Line laser, 670nm, <1mW (CL. 2)typ. 440mm (60mm...500mm)0.25mm / ±0.25mm0.25% FSR (full scale range)2kHz (NORMAL)
3.8kHz (FAST)
71.25x60x20


GENERAL TECHNICAL DATA:
Software Windows® PC software: L-LAS-LT-Scope
Voltage supply +24VDC (± 10%), reversed polarity protected, overload protected
Current consumption <200mA
Max. switching current 100mA, short-circuit proof
Light source L-LAS-LT-20-AL
L-LAS-LT-38-AL
L-LAS-LT-50-AL
L-LAS-LT-120-AL
►Halbleiterlaser, 670 nm, <0,39mW opt. Leistung, DC-Betrieb,
Laserklasse 1 gem. DIN EN 60825-1:2015-07 (IEC 60825-1:2014)

L-LAS-LT-165-AL
L-LAS-LT-250-AL
►Halbleiterlaser, 670 nm, <1mW opt. Leistung, DC-Betrieb,
Laserklasse 2 gem. DIN EN 60825-1:2015-07 (IEC 60825-1:2014)
Line detector CCD line detector with 512 pixels, 2048 subpixels
Reference distance L-LAS-LT-20-AL: 19.5mm
L-LAS-LT-38-AL: 40mm
L-LAS-LT-50-AL: 50mm
L-LAS-LT-120-AL: 120mm
L-LAS-LT-165-AL: 160mm
L-LAS-LT-250-AL: 250mm
Measuring range depends on sensor type
Resolution/reproducibility depends on sensor type
Linearity depends on sensor type
Laser line geometry depends on sensor type
Optical filter Interference filter, red light filter
Analog output (1x) ANA: Voltage 0...+10V or current 4...20mA
Digital outputs (3x) OUT0: (-) Measuring value < lower tolerance threshold
OUT1: (+) Measuring value > upper tolerance threshold
OUT2: (ok) Measuring value within tolerance window
pnp bright-switching/npn darks-switching or
pnp dark-switching/npn bright-switching
Output polarity can be adjusted under Windows® on PC
Digital inputs (2x) IN0: External trigger
IN1: Teach/Reset (double function)
Input voltage +Ub/0V, with protective circuit
Sensititivy adjustable under Windows® on PC
Laser power correction adjustable under Windows® on PC
Temperature stability 0.01% of measuring range/°C
LED display 2x two-color LED red/green and
1x two-color LED yellow/green for tolerance band monitoring:
red (+): Measuring value > upper tolerance threshold
red (-): Measuring value < lower tolerance threshold
green (ok): Measuring value within tolerance window
1x two-color LED yellow/green (multifunctional):
yellow: power indicator
Scan frequency max. 2kHz (at video speed = NORMAL) or
max. 3.8kHz (at video speed = FAST)
Interface RS232, parameterizable under Windows®
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in black
Type of connector - to PLC: 8-pole fem. connector Binder 712
- to PC: 4-pole fem. connector Binder 707
Connecting cables - to PLC: cab-las8/SPS
- to PC: cab-las4/PC, cab-4/USB or cab-4/ETH
Operating temp. range -10°C ... +50°C
Storage temp. range -20°C ... +85°C
Enclosure rating Electronics: IP54, optics: IP67
EMC test acc. to DIN EN 60947-5-2





TOP