Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

GLOSS-LAS Series

Inline Gloss Control Sensors


General technical data ....

Type Standard measuring angleWorking distanceLight sourceLaser line geometryLxWxH (mm) Data
sheet
CAD
data
Appl.
GLOSS-LAS-15-60° 60° gloss detection (for all common surfaces)15mm ± 10%Laser, 670nm, Po<1mW (CL. 2)at 15mm working distance: typ. 0.1mm x 3mm160x50x40


GENERAL TECHNICAL DATA:
Software Windows® PC software: GLOSS-Scope
Voltage supply +24VDC (± 10%), reversed polarity protected, overload protected
Current consumption <100mA
Max. switching current 100mA, short-circuit proof
Transmitter (light source) Semi-conductor laser, 670 nm, <1mW opt. power, AC-operation,
laser class 2 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014)
Working distance depends on sensor type
Size of light spot depends on sensor type
Optical filter depends on sensor type
Ambient light up to 5000 Lux
Interface RS232, parameterisable under Windows®
Switching frequency max. 60 kHz
Outputs digital (3x) OUT0...OUT2 (Qinv or Q, adjustable via PC)
Output analog (1x) 0...+10V or 4...20mA (can be switched via Windows®)
Input digital (2x) IN0: to trigger the Scope function
IN1: to trigger the analog output value
Tolerance range for
digital outputs
parameterisable under Windows®
Transmitter light power adjustable via Windows®
Averaging max. 32768 values (adjustable via Windows®)
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in black
Type of connector - to PLC: 8-pole fem. connector Binder 712
- to PC: 4-pole fem. connector Binder 707
Connecting cables - to PLC: cab-las8/SPS
- to PC: cab-las4/PC, cab-4/USB or cab-4/ETH
Operating temp. range -20°C ... +55°C
Storage temp. range -20°C ... +85°C
Enclosure rating IP54
EMC test acc. to DIN EN 60947-5-2
Accessories GLOSS-...-CAL (calibration unit)
GLOSS-...-OFL (offline unit)
ABL-GLOSS-... (blast air top)





TOP