R-LAS-LT Series
Laser Reflex Sensors (Triangulation Sensors)General technical data ....
GENERAL TECHNICAL DATA:
Software | Windows® PC software: R-LAS-LT-Scope V1.1 (LT-Scope V1.1) |
Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
Current consumption | <110mA |
Max. switching current | 100mA, short-circuit proof |
Light source | Semi-conductor laser, 670 nm, <1mW opt. power, DC-operation, Laser class 2 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Reference distance | depends on sensor type |
Working range | depends on sensor type |
Min. detectable object | depends on sensor type |
Beam geometry | depends on sensor type |
Optical filter | with R-LAS-LT-170, R-LAS-LT-170-XL: interference filter and red light filter with R-LAS-LT-110-HD2: red light filter |
Ambient light | up to 5000 Lux |
Operating mode | Alternating light (100 kHz) |
Inputs/outputs | depends on sensor type |
Switching frequency | depends on sensor type (and on parameter setting) |
Pulse lengthening | parameterizable under Windows® |
Bright-/dark switching | parameterizable under Windows® with R-LAS-LT-110-HD2: in addition also via an switch integrated in the sensor housing |
Laser power adjustment | parameterizable under Windows® |
Switching hystersis | parameterizable under Windows® |
Switching state indicator | with R-LAS-LT-110-HD2: by means of a yellow LED integrated in the sensor housing |
Operating indicator | with R-LAS-LT-110-HD2: by means of a green LED integrated in the sensor housing |
Averaging | parameterizable under Windows®: 1 to 64 values |
Housing dimensions | depends on sensor type |
Housing material | Aluminum, anodized in blue |
Type of connector | with R-LAS-LT-170, R-LAS-LT-170-XL: - to PLC: 4-pole M8-connector - to PC: 5-pole fem. connector Binder 712 with R-LAS-LT-110-HD2: - to PLC: 4-pole M12-connector - to PC: 5-pole fem. connector Binder 712 |
Connecting cables | with R-LAS-LT-170, R-LAS-LT-170-XL: - to PLC: cab-M8/4 - to PC: cab-las5/PC, cab-5/USB or cab-5/ETH with R-LAS-LT-110-HD2: - to PLC: cab-M12/4 - to PC: cab-las5/PC, cab-5/USB or cab-5/ETH |
Operating temp. range | -20°C ... +55°C |
Storage temp. range | -20°C ... +85°C |
Enclosure rating | IP67 |
EMC test acc. to | DIN EN 60947-5-2 |
Interface | RS232 |