Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

R-LAS-LT Series

Laser Reflex Sensors (Triangulation Sensors)


General technical data ....

Type Light sourceRefer- ence distanceWorking distanceBeam geometryMin. detect. objectSwitch. fre- quencyInputs/ outputsLxWxH (mm) Data
sheet
CAD
data
Appl.
R-LAS-LT-110-HD2 Laser, 670nm, <1mW
(CL. 2)
110mm110mm±1.5mmSpot size in focus: typ. Ø 0.3mm0.3mm3kHz1xDIG IN, 1xREF105x40x49.7


GENERAL TECHNICAL DATA:
Software Windows® PC software: R-LAS-LT-Scope V1.1 (LT-Scope V1.1)
Voltage supply +24VDC (± 10%), reversed polarity protected, overload protected
Current consumption <110mA
Max. switching current 100mA, short-circuit proof
Light source Semi-conductor laser, 670 nm, <1mW opt. power, DC-operation,
Laser class 2 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014)
Reference distance depends on sensor type
Working range depends on sensor type
Min. detectable object depends on sensor type
Beam geometry depends on sensor type
Optical filter with R-LAS-LT-170, R-LAS-LT-170-XL:
interference filter and red light filter
with R-LAS-LT-110-HD2:
red light filter
Ambient light up to 5000 Lux
Operating mode Alternating light (100 kHz)
Inputs/outputs depends on sensor type
Switching frequency depends on sensor type (and on parameter setting)
Pulse lengthening parameterizable under Windows®
Bright-/dark switching parameterizable under Windows®
with R-LAS-LT-110-HD2:
in addition also via an switch integrated in the sensor housing
Laser power adjustment parameterizable under Windows®
Switching hystersis parameterizable under Windows®
Switching state indicator with R-LAS-LT-110-HD2:
by means of a yellow LED integrated in the sensor housing
Operating indicator with R-LAS-LT-110-HD2:
by means of a green LED integrated in the sensor housing
Averaging parameterizable under Windows®:
1 to 64 values
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in blue
Type of connector with R-LAS-LT-170, R-LAS-LT-170-XL:
- to PLC: 4-pole M8-connector
- to PC: 5-pole fem. connector Binder 712
with R-LAS-LT-110-HD2:
- to PLC: 4-pole M12-connector
- to PC: 5-pole fem. connector  Binder 712
Connecting cables with R-LAS-LT-170, R-LAS-LT-170-XL:
- to PLC: cab-M8/4
- to PC: cab-las5/PC, cab-5/USB or cab-5/ETH
with R-LAS-LT-110-HD2:
- to PLC: cab-M12/4
- to PC: cab-las5/PC, cab-5/USB or cab-5/ETH
Operating temp. range -20°C ... +55°C
Storage temp. range -20°C ... +85°C
Enclosure rating IP67
EMC test acc. to DIN EN 60947-5-2
Interface RS232





TOP