Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

Praktische Beispiele aus dem industriellen Einsatz


1) Einsatzbereich auswählen:
    Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik)


2) Sprache auswählen:


Daten-
blatt:


APP N° 662

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
Controle de jatos de pulverização extremamente fracos
A presença e a densidade de um jato de pulverização extremamente fraco devem ser monitoradas.

Ultra-low spray jet control
The presence as well as the density of an ultra-low spray jet should be controlled.
Daten-
blatt:


APP N° 535

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Controle de cor de anéis de cor nas seringas
A cor das marcas de cor, aplicada nas seringas, deve ser controlada.

Color mark control on syringes
The color of the mark on syringes should be controlled.
Daten-
blatt:


APP N° 512

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Controle de presença de furos num tubo de cateter
A presença de furos nos cateteres deve ser monitorada.

Hole presence control on catheter tubes
The presence of holes on catheter tubes should be controlled.
Daten-
blatt:


APP N° 511

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Controle de presença de um arredondamento num cateter
A presença de um arredondamento num cateter deve ser monitorada.

Catheter dome presence control
The presence of a dome at the end of a catheter should be controlled.
Daten-
blatt:


APP N° 451

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da posição de um tampão de borracha mesmo antes da colocação na seringa de injeção
O posicionamento correto de um tampão de borracha deve ser monitorado antes de fechar a seringa de injeção.

Position monitoring of a rubber plug before the final positioning in a syringe
The position of a rubber plug should be controlled with regard to the outer face and inner surface.
Daten-
blatt:


APP N° 447

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Diferenciação de cor das tampas de plástico para seringas
Devem ser controladas as tampas de plástico que são usadas nas seringas de vidro. Tendo em atenção, que as tampas de plástico são ligeiramente transparentes e a superfície da tampa muito brilhante.

Color differentiation of plastic caps for syringes
Plastic caps used for syringes should be color controlled. It has to be taken into account, that the plastic caps are semitransparent and the surface is very glossy.
Daten-
blatt:


APP N° 319

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Diferenciação de seringas com e sem revestimento
Através de sistema retroreflexivo, deve-se identificar quando as seringas receberam revestimento externo e indicar ao usuário, caso alguma unidade sem revestimento seja detectada pelo sistema.

Differentiation of coated and uncoated syringes
Coated syringes should be distinguished from uncoated syringes.
Daten-
blatt:


APP N° 310

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção de falta de adesivos em esparadrapos
Deve-se inspecionar esparadrapos, procurando falhas em seu revestimento.

Detection of a gap on adhesive plaster
The presence of a gap of the tape on an adhesive plaster should be detected.
Daten-
blatt:


APP N° 308

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da presença de etiquetas fluorescentes em sacos plásticos
Graças à presença de materiais fluorescentes na composição das etiquetas, pode-se utilizar sensores da linha UV para realizar a detecção das mesmas.

Presence control of plaster in a transparent plastic bag
The presence of plaster in a transparent plastic bag should be controlled. At this, a part of the plaster is fluorescent if UV light is used.
Daten-
blatt:


APP N° 294

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da espessura de isolantes de alumínio de alto brilho
A espessura de diferentes modelos de isolantes de alumínio deve ser mensurada. Como as alturas entre as esteiras transportadoras e os isolantes de alumínio variam muito pouco, pode-se utilizar as esteiras transportadoras como referência.

Thickness control of shiny aluminum cushions
The thickness of different shiny aluminum cushions should be measured. These aluminum cushions are used for heat insulation. At this, the cushions will be transported on a conveyor belt with a very small fluctuation in height, thus the distance to the belt can be used as a reference.
Daten-
blatt:


APP N° 270

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Diferenciação da frente e do verso de componentes de algodão
Graças ao fato de a face traseira do material (não estruturada) possuir componentes fluorescentes, pode-se distingui-lo da parte frontal, que, apesar de também possuir componentes fluorescentes, possui um filme plástico que amortece o efeito fluorescente das partículas sob a ação de luz UV.

Differentiation of front- and backside of a fleece
The front side of a fleece should be differentiated from the back side. The back side (non structured side) is UV fluorescent, whereas the plastic structured film is nonfluorescent and damps the fluorescence.
Daten-
blatt:


APP N° 266

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção do ponto de corte de cintas pretas não-metálicas
Através de sistema retroreflexivo, deve-se identificar as mudanças de fase do material, indicando ponto correto de corte ao maquinário.

Detection of the section point on black nonmetallic strapping
The section point on a shiny black nonmetallic strapping should be detected optically in the reflective way.
Daten-
blatt:


APP N° 257

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção de revestimento transparente em vedações de borracha
Diferentes modelos de vedação devem ser controlados com o mesmo sensor, onde o spot de luz deve caber no menor modelo de vedação e, naturalmente, também entregar resultados excelentes para as vedações maiores.

Detection of transparent coating on rubber seals
The coating of rubber seals should be detected. At this, different types should be controlled with the same sensor, thus the spot size of the sensor must fit to the smallest rubber size and should of course deliver proper results from the bigger seals, too.
Daten-
blatt:


APP N° 252

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção do ponto de corte de cintas brancas não-metálicas
Através de sistema retroreflexivo, deve-se identificar as mudanças de fase do material, indicando ponto correto de corte ao maquinário.

Cutoff point detection of white nonmetallic strapping
The cutoff point of white nonmetallic strapping should be detected in a reflective way.
Daten-
blatt:


APP N° 222

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da presença de mangas em agulhas
Deve-se diferenciar as agulhas não conformes das agulhas completas, coibindo o envio de materiais com este tipo de falha de qualidade ao cliente final.

Sleeve presence control on an injection needle
The presence of a sleeve on an injection needle should be controlled.
Daten-
blatt:


APP N° 207

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção de lacunas entre absorventes durante o transporte contínuo em esteiras
Os absorventes serão transportados entre duas faixas de apoio. Tanto o começo quanto o fim do absorvente devem ser identificados. Deve-se ainda identificar a ausência de absorventes, checando-se a presença contínua dos mesmos. Caso o sensor identifique o começo e o término de um absorvente, logo em seguida o sensor deve identificar a passagem de mais um absorvente. Caso isto não ocorra, o alerta de ausência de produtos é fornecido pelo sistema. A única forma prática de realizar esta tarefa é através de um sistema tipo barreira, utilizando o princípio da opacidade.

Detection of a gap between successive hygiene articles during the transportation in a conveyor belt
Panty liners will be transported between two belts. The beginning as well as the end of a panty liner should be detected. Furthermore, a gap between two successive panty liners should be detected. The only practicable possibility is to look through the two conveyor belts.
Daten-
blatt:


APP N° 203

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da presença de mangas em agulhas
Deve-se diferenciar as agulhas não conformes das agulhas completas, coibindo o envio de materiais com este tipo de falha de qualidade ao cliente final.

Presence control of the sleeve on an injection needle
The presence of a sleeve should be controlled.
Daten-
blatt:


APP N° 198

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da cor de sangue em tubos de ensaio
Após reações em tubos de ensaio, a cor do sangue é alterada e deve ser detectada pelos sensores de cor.

Color control of blood in a laboratory glass
Blood in a laboratory glass with different liquid level should be color controlled.
Daten-
blatt:


APP N° 184

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle de dupla camada de lã
Deve-se diferenciar entre uma e duas camadas de materiais feitos de lã.

Double layer control of fleece material
It should be differentiated between one and two layers of a fleece material.
Daten-
blatt:


APP N° 162

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da presença de etiquetas em almofadas para amamentação
Deve-se detectar a presença de etiquetas brancas em almofadas, também brancas, garantindo que todas as almofadas produzidas sejam entregues com esta demarcação.

Presence control of a label on a nursing pad
The presence of a label on a nursing pad should be controlled.
Daten-
blatt:


APP N° 147

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da posição de barbantes em absorventes
Deve-se controlar a correta posição de barbantes na parte traseira dos absorventes, onde, uma posição “correta” significa dizer que, neste caso, o barbante da cor ciano deve cobrir praticamente toda a parte traseira do absorvente, sendo o controle realizado através de um filme plástico transparente.

Position control of a thread on a tampon
The right position of a thread on the backside of a tampon should be controlled. Right position means in this case, that the cyan colored thread should cover nearly the whole backside of the tampon. The position of the thread must be checked through a transparent plastic film.
Daten-
blatt:


APP N° 143

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle do posicionamento de fechos Velcro
Deve-se identificar a orientação das faces de fechos Velcro, garantindo que os mesmos serão utilizados sempre com a orientação correta.

Position monitoring of hook-and-loop fasteners
The orientation of Velcro® fasteners should be controlled.
Daten-
blatt:


APP N° 111

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da queda de gotas com sistema a laser tipo barreira
Tanto o número quanto o volume de cada uma das gotas que passam pelo sistema devem ser controlados.

Drop control with a laser through beam system
The number as well as the volume of drops should be controlled.
Daten-
blatt:


APP N° 105

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle de jatos spray
A densidade de jatos spray deve ser controlada, visando detectar falhas de qualidade.

Spray jet amount control
The density of the spray jet should be controlled.
Daten-
blatt:


APP N° 92

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Diferenciação da coloração de tampas de seringas
Além da coloração, deve-se identificar mudanças bruscas e inaceitáveis da cor de um lote para outro das tampas.

Color differentiation of syringe capsules
Syringe capsules must be color differentiated. At this, there should be detected also an unacceptable color change from batch to batch of the same capsule type.
Daten-
blatt:


APP N° 25

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção de marcações coloridas em fraldas descartáveis
Marcações de diferentes colorações, utilizadas como referência, devem ser identificadas através de um sistema inline. A máxima velocidade de produção é de 10m/s.

Detection of color marks on disposal diapers
Different color marks (different in color) should be detected with an inline sensor. The maximum production speed is 10 m/s.
Daten-
blatt:


APP N° 11

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção inline da borda de bandas perfuradas em fraldas
Durante a montagem de fraldas, a presença, bem como a posição das bandas, deve ser identificada.

Inline edge detection of a white label on a white diaper
During the assembly of diapers, the presence as well as the position of the label must be controlled.
Daten-
blatt:


APP N° 4

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção da presença de lã durante a fabricação de fraldas descartáveis
A velocidade de produção é de aproximadamente 10m/s e a altura das fraldas possui uma leve variação. Com relação às cores, tanto a fralda quanto a lã são brancas, no entanto, a lã se torna fluorescente sob a influência de luz UV.

Detection of the presence of the fleece during the production of disposable diapers
During the production of disposable diapers the assembling of the fleece must be checked. The production speed is approximately up to 10m/s and the height of the diapers can slightly changing. Furthermore the color of the diaper as well as the color of the fleece is white but additionally to this the fleece is fluorescent in blue under the influence of UV light.
Daten-
blatt:


APP N° 3

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detecção da correta orientação de fitas laminadas (frente/verso)
Deve-se identificar a orientação de laminas impermeáveis, garantindo a não inversão das faces. No caso de uma inversão, o lado não impermeável ficará exposto, comprometendo a eficiência do sistema.

Detection of the correct direction of a laminated band (front side/back side detection)
The direction of a laminated band (Gore laminated band) must be controlled. The color of the band can be white, black or red.
Daten-
blatt:


APP N° 2

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Controle da orientação de fechos de Velcro®
Deve-se identificar a orientação de fechos Velcro, a fim de evitar a incorreta montagem e envio ao cliente final, pois prejudica a fixação dos componentes.

Hook-and-pile fastener (Velcro®) direction control
The task is to check the direction of the hook-and-pile fastener.


AKTUELLES

Messeteilnahmen:

 •   IFAT Munich 2024
 •   SPS Italia 2024
 •   FIP 2024
 •   PRS Europe 2024
 •   SKZ-Innovationstag Recycling
 •   SKZ-Netzwerktag
 •   SKZ-Technologietag
 
•   PRS Middle East & Africa 2024
 •   Plastics Recycling World Expo
     
Europe 2024
 •   Plastics Recycling World Expo
     
North America 2024
 •   PRS Asia 2024
 •   PRS India 2024
 •   European Coatings Show 2025

mehr...


Fachartikel:

  Rezyklate direkt beim Spritzgießen und der Extrusion prüfen
NIR-Verfahren zur Inline-Kontrolle von Recycling-kunststoffen
Kunststoffe 2/2024

 

mehr ...


Pressemitteilungen:

Inline-Farbkalibrierung auf Kunststoffrezyklate
(Inline-Farbmesssysteme)

 
Testbericht zur Inline-Farbmessung an Rezyklaten
(Inline-Farbmesssystem)

mehr ...


Whitepaper:

Sensorsysteme zur Rezyklat-Kontrolle in der Kunststoffindustrie fürs Labor und Inline
Kontrolle der Kunststoffart von Rezyklaten und Neuware mit Hilfe der NIR-Technologie

mehr ...


Applikationen:

Detektion von Dellen und Beulen auf Metall-Stanzbändern
(N° 801)
Unterscheidung von Leder-, Textil- und Kunststoff- Interieurkomponenten
(N° 802)
Farbmessung von Kunststoffdeckeln
(N° 803)

mehr...


WAS IST ...
... Oberflächenspannung?
... Ölverdunstung?
... Ölschichtdickenmessung?

mehr...


Software-Neuheiten:

SPECTRO3-MSM-DIG-Scope V1.5 (2021.10.20)
V1.5.2

mehr...



FIND US ON ....

Facebook X (Twitter) Instagram Youtube in

 








TOP