N° 559
|
Presence control of fluorescent coating
The presence of a fluorescent coating on rubber seal should be controlled.
|
|
N° 516
|
Fluorescent thread presence control in diapers during the production
The presence of fluorescent threads in diapers should be inline controlled.
|
|
N° 493
|
Fluorescence detection on metal foils
The presence of fluorescence coating on a metal foil should be controlled.
|
|
N° 474
|
Detection of fluorescent oil on flat washers
The presence of oil on different flat washers should be controlled. It has to be taken into account, that the oil is fluorescent, if UV light is used.
|
|
N° 473
|
Detection of fluorescent lubricant on metal pins
Fluorescent lubricant should be detected on metal pins.
|
|
N° 456
|
Glue detection on the thread of a screw
The presence and amount of fluorescent (fluorescent under the influence of UV light) glue on the thread of a screw should be detected.
|
|
N° 424
|
Oil drop presence control on a steel surface
The presence of an oil drop on a steel surface should be controlled.
|
|
N° 421
|
Fluorescent glue strip detection on a plastic bag
A glue strip, which becomes fluorescent in the presence of UV light, should be detected on a plastic bag. At this, the glue strip is covered with a transparent plastic film.
|
|
N° 410
|
Frequency control of turbo charger wheels
The frequency of turbo charger wheels should be controlled. At this, one of the blades of the wheel is coated with a fluorescent transparent lacquer.
|
|
N° 330
|
Detectarea unei etichete transparente fluorescente pe un material suport transparent O etichetă transparentă din material plastic trebuie detectată pe o bandă transparentă din material plastic. Eticheta este fluorescentă sub influența luminii UV.
Detection of a transparent fluorescent label on transparent plastic film
A transparent plastic label should be detected on a transparent plastic film. It should be taken into account, that the label is fluorescent in using UV-light.
|
|
N° 321
|
Detectarea urmelor de clei pe hârtie de ambalaj Trebuie monitorizată existența unei urme de clei Aici trebuie ținut cont de faptul că urma de clei are proprietăți fluorescente.
Glue line detection on packaging paper
A glue line should be detected on packaging paper. At this, the glue is fluorescent if UV light is used.
|
|
N° 317
|
Detectarea benzilor fluorescente pe bilete Trebuie detectată o bandă fluorescentă sub influența luminii UV.
Fluorescent color stripe detection on tickets
A fluorescent color stripe on a ticket should be detected.
|
|
N° 295
|
Detectarea unui strat fluorescent pe o garnitură neagră de cauciuc Trebuie verificată existența unui strat acoperitor pe o garnitură de cauciuc. În acest scop se folosește un strat fluorescent care poate fi excitat cu ajutorul luminii UV (365nm … 385nm) și care apoi emite o lumină cu lungimea de undă a luminii albastre.
Detection of a fluorescent coating on black rubber seal
The coating on rubber seal should be detected. At this, a fluorescent coating with an excitation wavelength which lies in the UV range (around 365nm … 385nm) is used. This UV light will be converted from the fluorescent coating into the visible blue range.
|
|
N° 212
|
Detectarea unei etichete adezive fluorescente pe hârtie de cutii de țigarete Locul de lipit al hârtiei pentru cutii de țigarete constă dintr-o etichetă adezivă fluorescentă neagră. Sub incidența luminii UV, eticheta emite în domeniul albastru.
Detection of fluorescent labels on printed cigarette box paper
An adhesion surface area of printed cigarette box paper is marked with a fluorescent label. The task is to detect this fluorescent label.
|
|
N° 195
|
Diferențierea uleiurilor de motor Trebuie diferențiate diverse tipuri de ulei de motor. În acest scop se poate folosi fluorescența naturală a uleiurilor organice. De asemenea, diverși aditivi sunt adăugați la aceste uleiuri, astfel încât fluorescența să fie diferită sub acțiunea luminii UV.
Color differentiation of fluorescent oil
Different oil types which are used for engines should be differentiated. At this, the natural effect of UV fluorescence of mineral oil is used. Furthermore fluorescent liquid will be added to some of the mineral oils, which allows a differentiation of the adequate types.
|
|
N° 152
|
Verificarea existenței unei mase fluorescente de turnare într-o piesă strunjită Trebuie monitorizată prezența unei mase de turnare fluorescente într-o piesă strunjită. Masa de turnare luminează albastru sub influența luminii UV.
Detection of fluorescent cured glue on a shaft
On a shaft fluorescent glue is used to seal the intersection between the shaft and a roll.
|
|
N° 128
|
Verificarea culorii unei imprimări fluorescente pe un pachet de țigarete Trebuie monitorizate în timpul producției atât culoarea cât și intensitatea unei imprimări care este fluorescentă sub influența luminii UV. În acest scop trebuie ținut cont de faptul că pe suprafața cartonului există alte zone fluorescente, care totuși luminează albastru sub influența UV, în timp ce culoarea imprimării ce trebuie monitorizată emite o lumină verde.
Color control of a fluorescent lacquer on a cigarette box
The color as well as the intensity of a fluorescent lacquer on a cigarette box should be controlled. It should be noted that there are also other fluorescent marks on the cigarette box, but these colors are different (blue) from the fluorescent lacquer (green).
|
|
N° 116
|
Verificarea prezenței unei spatule din material plastic într-un ambalaj de medicament Trebuie interogată prezența unei spatule din material plastic, care sub influența luminii UV este albastru fluorescent, într-un ambalaj de medicament care la momentul interogării este încă deschis pe partea frontală.
Control of the presence of the spatula in a pharmaceutical box
The presence of a fluorescent spatula in a pharmaceutical box should be checked. During the tests the front side is open.
|
|
N° 98
|
Determinarea conținutului de ulei rezidual în apa uzată În timpul producției de uleiuri alimentare rezultă, în funcție de producție, apă uzată, care este transportată cu cantități reziduale de uleiuri organice. Conținutul permis de uleiuri în acest tip de emulsie trebuie să aibă, după procesul de curățare, o valoare de max. 500ppm.
Oil containing waste water detection
On an oil press the amount of oil in the waste water must be controlled. Typical values are 500ppm of flux oil in the waste water and the goal is to reach the 100ppm. At this the fluorescent effect of the flux oil can be used.
|
|
N° 88
|
Detectarea unei aplicări de adeziv fluorescent pe partea posterioară a unei benzi de șlefuit Aplicarea de adeziv pe partea posterioară a unei benzi de șlefuit trebuie interogată cu privire la o prezență neîntreruptă. Adezivul este fluorescent în spectrul de lungime de undă a luminii albastre, sub influența luminii UV. Distanța de la detector la banda abrazivă trebuie să fie de cca. 20mm și trebuie detectate goluri de adeziv încpând de la 2mm x 10mm.
Fluorescent glue control on an abrasive belt
During the production of abrasive belt material with a 10mm wide glue stripe the presence of the fluorescent glue must be observed. Defects greater than 2mm in length must be proper detected. The distance of the sensor head to the object should be approximately 20mm and the detecting range around 2mm x 10mm.
|
|
N° 75
|
Detectarea marcajelor de culoare în controalele longitudinale și transversale ale registrelor În domeniul de tipărit offset se folosesc marcaje tipărite trapezoidale, corelate cu controalele longitudinale și transversale ale registrelor. Pentru fiecare culoare tipărită se folosește un marcaj de culoare și toate marcajele de culoare trebuie să fie aliniate pe marcajul negru de tipărire cu ajutorul controalelor registrelor.
Color mark detection for side and longitudinal register control in the printing industry
In the web offset printing trapezoid like color marks will be used for the side register as well as the longitudinal register control. For each color a color mark is used, at which all color marks will be synchronized to the black color mark.
|
|
N° 47
|
Detectarea unui marcaj fluorescent pe o scândură Pe scânduri sunt marcate nodurile cu o culoare fluorescentă. Marcajul care este fluorescent albastru-verziu sub influența luminii UV are o lățime de 15mm și se poate întâmpla să fie aplicate două dungi de această lățime, care sunt amplasate la o distanță de 20mm una de alta. Marcajele trebuie să fie detectate cu un senzor de la o distanță de 200mm; de asemenea, trebuie detectate și marcaje cu o lățime de 5mm.
Color detection of fluorescent marks on wood plates
On wooden plates defects will be marked with a fluorescent marker. The fluorescent mark has normally a width of about 15mm and it can happen, that two of this marks lie 20 mm away of each other, but must be detected as two separate marks. Furthermore the fluorescent marks should be detected at a distance of 200 mm to the object and even a mark with a width of 5mm should be detected.
|
|