Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

Accessories FIO Series:Mounting units

for fiber optics through-beam (type D-...) or BICONE fiber optics


General technical data ....

Type For use withCharacteristicsLxWxH (mm) Data
sheet
CAD
data
Appl.
C-MOUNT-A2.0-180°-22/50 D-...-A2.0-...Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 22mm70x60x10
Appl.
C-MOUNT-A2.0-180°-60/50 D-...-A2.0-...Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 60mm108x60x10
Appl.
C-MOUNT-A2.0-180°-100/50 D-...-A2.0-...Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 100mm148x60x10
C-MOUNT-A3.0-180°-16/50 D-...-A3.0-...Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 16mm70x60x12
C-MOUNT-A3.0-180°-60/50 D-...-A3.0-...Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 60mm114x60x12
C-MOUNT-A3.0-180°-100/50 D-...-A3.0-...Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 100mm154x60x12
C-MOUNT-Q1-180°-50/50 D-S-Q1-(5x0.5)...-67°Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 50mm100x75x20
C-MOUNT-Q2-180°-50/50 D-S-Q2-(10x0.3)-...-67°Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 50mm110x80x20
C-MOUNT-Q3-180°-50/50 D-S-Q3-(18x0.3)-...-67°Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 50mm120x89x20
C-MOUNT-Q4-180°-50/50 D-S-Q4-(28x0.2)-...-67°Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 50mm160x99x20
C-MOUNT-Q5-180°-50/50 D-S-Q5-(38x0.15)-...-67°Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 50mm160x109x20
C-MOUNT-Q6-180°-50/50 D-S-Q6-(48x0.15)-...-67°Rectangular design with a housing depth = 50mm, angle of the optics to each other = 180°, distance of the optics to each other = 50mm160x119x20
C-MOUNT-2x-KL-5-180°-30/80 2x KL-5-R1.1Rectangular design with a housing depth = 80mm, angle of the optics to each other = 180°, distance of the optics to each other = 30mm130x95x20
MOUNT-A2.0-40°-20 D-...-A2.0-...Angle of the optics to each other = 40° (2x20°), distance to the object = 20mm49.3x31.7x10
MOUNT-A2.0-45°-10 D-...-A2.0-...Angle of the optics to each other = 45°, distance to the object = 10mm40.23x36x10
Appl.
MOUNT-A2.0-90°-15 D-...-A2.0-...Angle of the optics to each other = 90° (2x45°), distance to the object = 15mm89.2x33.9x10
MOUNT-A2.0-120°-12 D-...-A2.0-...Angle of the optics to each other = 120° (2x60°), distance to the object = 12mm121x31x10
Appl.
MOUNT-A2.0-150°-10 D-...-A2.0-...Angle of the optics to each other = 150° (2x75°), distance to the object = 10mm181.1x32.1x10
MOUNT-A2.0-170°-5 D-...-A2.0-...Angle of the optics to each other = 170° (2x85°), distance to the object = 5mm328.7x32.2x10
MOUNT-A2.0/A2.0-0°/0°-7 BICONE fiber optics (A2.0)Parallel guided optics, at a distance of 7 mm24x21x15
MOUNT-A3.0-40°-20 D-...-A3.0-...Angle of the optics to each other = 40° (2x20°), distance to the object = 20mm49.3x31.7x10
MOUNT-A3.0-45°-0 R-S-A3.0-(3.0)-...-67°-(1P+1BP) + R-S-A3.0-(3.0)-...-67°Color measurement according to the 45°/0° and the 0°/45° method. The front end is placed in contact on the surface to be measured.40x42x20
MOUNT-A3.0-45°-10 D-...-A3.0-...Angle of the optics to each other = 45°, distance to the object = 10mm40.23x36x10
Appl.
MOUNT-A3.0-90°-15 D-...-A3.0-...Angle of the optics to each other = 90° (2x45°), distance to the object = 15mm89.2x33.9x10
MOUNT-A3.0-120°-12 D-...-A3.0-...Angle of the optics to each other = 120° (2x60°), distance to the object = 12mm121x31x10
MOUNT-A3.0-150°-10 D-...-A3.0-...Angle of the optics to each other = 150° (2x75°), distance to the object = 10mm181.1x32.1x10
MOUNT-A3.0-170°-5 D-...-A3.0-...Angle of the optics to each other = 170° (2x85°), distance to the object = 5mm328.7x32.2x10
MOUNT-A3.0/A3.0-0°/0°-9 BICONE fiber optics (A3.0)Parallel guided optics, at a distance of 9mm30x25x17
MOUNT-F3.0/A3.0-150° R-...-F3.0-... + R-...-A3.0-...Angle of the optics to each other = 150° (2x75°), special version71x24x18
MOUNT-R1.1-120°-12 D-...-R1.1-...Angle of the optics to each other = 120° (2x60°), distance to the object = 12mm122x31x14
MOUNT-R1.1/R1.1-0°/0°-7.5 BICONE fiber optics (R1.1)Parallel guided optics, at a distance of 7.5mm30x22x15
MOUNT-R2.1-120°-12 D-...-R2.1-...Angle of the optics to each other = 120° (2x60°), distance to the object = 12mm122x31x14
MOUNT-R2.1/R2.1-0°/0°-10.5 BICONE fiber optics (R2.1)Parallel guided optics, at a distance of 10.5mm30x28x18
MOUNT-KL-D30-VA KL-PLNG-BL-A3.0Mounting device for optical probe KL-PLNG-BL-A3.0547x78x500








TOP