L-LAS-TB-MS Series
Laser transmitted light line sensors (Master/Slave)General technical data ....
GENERAL TECHNICAL DATA:
Software | Windows® PC software: L-LAS-TB-MS-Scope |
Designs and variants | ►2-piece: Fork Master (-F-...-MA) + Fork Slave (-F-...-SL) ►4-piece: Receiver Master (-R-MA) + receiver Slave (-R-SL) + 2x transmitter (-T) ►6-piece: Electronic control unit Master (-CON1-MA) + electronic control unit Slave (-CON1-SL) + 2x transmitter (-T) + 2x receiver (-R) ►Variant: -4/20: Analog output 4...20mA (instead of 0...+10V) |
Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
Current consumption | <200mA |
Max. switching current | 100mA, short-circuit proof |
Light source | Semi-conductor laser, 670 nm, <0.39mW opt. power, DC-operation, Laser class 1 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Line detector | depends on sensor type |
Working distance | depends on sensor type |
Measuring range | depends on sensor type |
Resolution/reproducibility | depends on sensor type |
Linearity | depends on sensor type |
Optical filter | depends on sensor type |
Analog output | Voltage 0...+10V ►with variant -4/20: Current 4...20mA |
Digital outputs | OUT0, OUT1, OUT2: pnp bright-switching/npn dark-switching or pnp dark-switching/npn bright-switching Output polarity adjustable under Windows® on PC |
Digital inputs | IN0: External trigger IN1: Teach/Reset (double function) Input voltage +Ub/0V, with protective circuit |
Sensitivity | adjustable with potentiometer TOL or under Windows® on PC |
Laser power correction | adjustable under Windows® on PC |
Teach button | for norm value teaching or for reset of maximum values |
LED display | Master and Slave: LED red (+): Measuring value > upper tolerance threshold LED green: Measuring value within tolerance window LED red (-): Messwert < lower tolerance threshold LED yellow: LED for sensor adjustment (multifunctional) |
Scan frequency | depends on sensor type |
Interface | RS232, parameterizable under Windows® |
Housing dimensions | depends on sensor type |
Housing material | Aluminum, anodized in black |
Type of connector | ►with 2-piece desgin (2x fork): Master (-F-...-MA): - to PLC: 8-pole fem. connector Binder 712 - to PC: 4-pole fem. connector Binder 707 - to Slave: 7-pole fem. connector Binder 712 Slave (-F-...-SL): - to Master: 7-pole fem. connector Binder 712 ►with 4-piece design: Receiver Master (-R-MA): - to PLC: 8-pole fem. connector Binder 712 - to PC: 4-pole fem. connector Binder 707 - to receiver Slave (-R-SL): 7-pole fem. connector Binder 712 - to transmitter (-T): 3-pole fem. connector Binder 712 Receiver Slave (-R-SL): - to PLC: 8-pole fem. connector Binder 712 - to receiver Master (-R-MA): 7-pole fem. connector Binder 712 - to transmitter (-T): 3-pole fem. connector Binder 712 2x transmitter (-T): - to receiver Master and to receiver Slave: 3-pole fem. connector Binder 712 ►with 6-piece design: Electronic control unit Master (-CON1-MA): - to PLC: 8-pole fem. connector Binder 712 - to PC: 4-pole fem. connector Binder 707 - to electronic control unit Slave (-CON1-SL): 7-pole fem. connector Binder 712 - to transmitter (-T): 3-pole fem. connector Binder 712 - to receiver (-R): 7-pole fem. connector Binder 712 Electronic control unit Slave (-CON1-SL): - to PLC: 8-pole fem. connector Binder 712 - to electronic control unit Master (-CON1-MA): 7-pole fem. connector Binder 712 - to transmitter (-T): 3-pole fem. connector Binder 712 - to receiver (-R): 7-pole fem. connector Binder 712 2x transmitter (-T): - to electronic control unit Master (-CON1-MA) and to electronic control unit Slave (-CON1-SL): 3-pole fem. connector Binder 712 2x receiver (-R): - to electronic control unit Master (-CON1-MA) and to electronic control unit Slave (-CON1-SL): 7-pole fem. connector Binder 712 |
Connecting cable | ►with 2-piece design (2x fork): Master (-F-...-MA): - to PLC: cab-las8/SPS - to PC: cab-las4/PC, cab-4/USB or cab-4/ETH - to Slave (-F-...-SL): cab-las7-male ►with 4-piece design: Receiver Master (-R-MA): - to PLC: cab-las8/SPS - to PC: cab-las4/PC, cab-4/USB or cab-4/ETH - to receiver Slave (-R-SL): cab-las7-male - to transmitter (-T): cab-las3-male Receiver Slave (-R-SL): - to PLC: cab-las8/SPS - to transmitter (-T): cab-las3-male ►with 6-piece design: Electronic control unit Master (-CON1-MA): - to PLC: cab-las8/SPS - to PC: cab-las4/PC, cab-4/USB or cab-4/ETH - to electronic control unit Slave (-CON1-SL): cab-las7-male - to transmitter (-T): cab-las3-male - to receiver (-R): cab-las7-male Electronic control unit Slave (-CON1-SL): - to PLC: cab-las8/SPS - to transmitter (-T): cab-las3-male - to receiver (-R): cab-las7-male |
Operating temp. range | -10°C ... +50°C |
Storage temp. range | -20°C ... +85°C |
Enclosure rating | Electronics: IP54, Optics: IP67 |
EMC test acc. to | DIN EN 60947-5-2 |