Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

SPECTRO-1-CONLAS

Single-channel evaluation system


General technical data ....

Type Transmitter (light source)Measurement rangeDetection rangeLxWxH (mm)For use with Data
sheet
CAD
data
Appl.
SPECTRO-1-CONLAS via external sensor frontend: Laser (A-LAS-N-...-C or infrared (FK-...-LAS-IR)dep. on the frontend useddep. on the frontend used65x65x26A-LAS-N-...-C,
FK-...-LAS-IR
Appl.
SPECTRO-1-CONLAS-ANA-SC via external sensor frontend: Laser (A-LAS-...-C)dep. on the frontend useddep. on the frontend used65x65x26A-LAS-...-C for punching stroke control (monitoring of the punching process of paper strips or metal as well as plastic strips)


GENERAL TECHNICAL DATA:
Software Windows® PC software: SPECTRO1-Scope
Voltage supply +24VDC (± 10%), reserve polarity protected, overload protected
Current consumption <160mA
Max. switching current 100mA, short circuit proof
Switching state indication 2 yellow LEDs (OUT0 and OUT1)
Inputs digital (2x) IN0 and IN1 (0V/+24V)
Outputs digital (2x) OUT0 and OUT1 (0V/+24V)
Output analog (1x) Voltage 0...+10V or current 4...20mA (adjustable via PC software)
Interface RS232 (USB and Ethernet converter available)
Pulse lengthening 0...100ms, abjustable via PC software
Averaging max. 32768 values, adjustable via PC software
Scan frequency LED operation, adjustable via PC software:
- AC operation: max. 50kHz (depends on parameterization)
- DC and OFF operation: max. 175kHz (depends on parameterization)
Switching frequency max. 60kHz
Analog band width max. 90kHz (-3dB)
Transmitter (light source) depends on the frontend used
Transmitter control can be switched via PC software:
AC operation (LED MODE-AC),
DC operation (LED MODE -DC),
OFF operation (LED MODE-OFF)
Measuring range depends on the frontend used
Receiver depends on the frontend used
Gain Receiver gain setting:
8 steps (AMP1...AMP8), adjustable via PC software
Ambient light max. 5000 Lux
Detection range depends on the frontend used
Reproducibility 2 digits at 12-bit A/D conversion
Housing dimensions depends on the frontend used
Housing material Aluminum, anodized in black (if optics holding device: anodized)
Connectors - to PLC: 8-pole fem. connector Binder 712
- to PC: 4-pole fem. connector Binder 707
- to the frontend: 2x 7-pole fem. connector Binder 712
Connecting cables - to PLC: cab-las8/SPS
- to PC: cab-las4/PC, cab-4/USB or cab-4/ETH
Operating temp. range -20°C ... +55°C
Storage temp. range -20°C ... +85°C
Enclosure rating IP64
EMC test acc. to DIN EN 60947-5-2






TOP