GLOSS Series
Inline Gloss Meters
GENERAL TECHNICAL DATA:
| Software | Windows® PC software: GLOSS-Scope |
| Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
| Current consumption | <100mA |
| Max. switching current | 100mA, short-circuit proof |
| Measurement geometry | Standard measurement angles: ► 20°: For high-gloss surfaces A 20° gloss sensor is used if gloss grades >70GU are to be determined. That is, if the gloss grade measured with a 60° gloss meter is >70GU, a 20° gloss sensor is used. ► 45°: TAPPI standard (paper industry) for glossy surfaces ► 60°: For semi-gloss surfaces A 60° gloss sensor is used if gloss grades >10GU and <70GU are to be determined. This variant is an "all-rounder". The 60° gloss sensor is therefore standard for most applications. ► 75°: TAPPI standard (paper industry) for matt surfaces ► 85°: For matt surfaces An 85° gloss sensor is used when gloss grades <10GU are to be determined. That is, if the gloss grade measured with a 60° gloss meter is <10GU, an 85° gloss sensor is used. [GU = Gloss Unit] |
| Light source | depends on sensor type |
| Working distance | depends on sensor type |
| Size of light spot | depends on sensor type |
| Optical filter | depends on sensor type |
| Ambient light | up to 5000 Lux |
| Interface | RS232, parameterisable under Windows® |
| Scan frequency | in LED operation AC: max. 22100 Hz in LED operation DC: max. 61750 Hz |
| Switching frequency | max. 60 kHz |
| Outputs digital (3x) | OUT0...OUT2 (Qinv or Q, adjustable via PC) |
| Output analog (1x) | 0...+10V or 4...20mA (can be switched via Windows®) |
| Input digital (2x) | IN0: to trigger the Scope function IN1: to trigger the analog output value |
| Tolerance range for digital outputs |
parameterisable under Windows® |
| Transmitter light power | adjustable via Windows® |
| Averaging | max. 32768 values (adjustable via Windows®) |
| Housing dimensions | depends on sensor type |
| Housing material | Aluminum, anodized in black |
| Type of connector | - to PLC: 8-pole fem. connector Binder 712 - to PC: 4-pole fem. connector Binder 707 |
| Connecting cables | - to PLC: cab-las8/SPS - to PC: cab-las4/PC, cab-4/USB or cab-4/ETH |
| Operating temp. range | -20°C ... +55°C |
| Storage temp. range | -20°C ... +85°C |
| Enclosure rating | IP54 |
| EMC test acc. to | DIN EN 60947-5-2 |
| Accessories | GLOSS-...-CAL (calibration unit) GLOSS-...-OFL (offline unit) ABL-GLOSS-... (blast air top) |